Examples of 'implant surface' in a sentence

Meaning of "implant surface"

implant surface: This phrase refers to the outer layer or coating of an implantable medical device, such as a dental implant or a prosthetic joint. It denotes the part of the implant that comes into direct contact with the surrounding tissue or bone, playing a crucial role in the device's stability, integration, and functionality

How to use "implant surface" in a sentence

Basic
Advanced
implant surface
This can be emulated by an etched implant surface.
Implant surface promotes integration with the bone.
Surface treatment for an implant surface.
Such an implant surface is thus covered by a titanium oxide layer.
A conformer coating on the rough implant surface is needed.
Implant surface preparation.
These ions react chemically or electrochemically on the implant surface.
The features of an implant surface determine osteogenesis in the initial stages of osseointegration.
Such porous structures are normally attached to the implant surface by sintering.
Blood clot formation on the implant surface may favor the osseointegration process in this phase.
Such porous structures are occasionally attached to the implant surface by sintering.
The skin was attached to the implant surface by means of fresh granulation tissue.
The method may further comprise an anodizing of the implant surface.
Preferably no significant etching of the implant surface occurs with the present treatment.
A current paradigm in biomaterials is the control of protein adsorption on the implant surface.

See also

Perivascular cells also migrate to the implant surface where they will differentiate into new osteoblasts.
Other methods involve altering of the chemical properties of the implant surface.
Cleaning a metal implant surface from contaminants ;.
This is associated with a problem related to fixation of the antibiotic on the implant surface.
As a result, the implant surface has a predetermined surface roughness.
The extracted mathematical descriptors are fed into an implant surface generation module.
Thus, an implant surface roughness may also be obtained by providing a thicker oxide layer.
The analgesics may vary in concentration in a direction extending perpendicular to the implant surface.
Such a structure results in a medical device surface or implant surface of large specific surface área.
These particles shall enable controlled release of the antibiotics substances from the implant surface.
Deoxidizing said cleaned metal implant surface of step a in medium ;.
Companies have tried to improve the dental implant by making changes to the implant surface.
Often, nanoparticles are applied to the implant surface as particle coatings.
The HF reacted with and removed the native titanium dioxide layer from the implant surface.
Indeed, inflammatory cells at the implant surface often maintain a flat morphology.
The acid etching may include removing a native oxide layer from the implant surface.
The implant surface is preferably a metallic implant surface, such as a titanium implant surface.
This interface construction during the osseointegration process has the implant surface as a key determinant.
First, the implant surface may generally inhibit a broad-spectrum of bacterial activity.
Most preferably, there is substantially no etching of the implant surface.
Furthermore, the implant surface may be dried and sterilized after said rinsing step.
This results in a liquid-powder coating on the medical implant surface to be coated.
In addition, the peaks of the implant surface do not easily fracture from the implant.
The peptide advantageously promotes cell-adhesion of specific cells to the implant surface.
Contacting said cleaned implant surface of step a with a bioactive conjugate of claim 1 in a nitrogen medium.
More specifically, an initial iteration of the overall implant surface model is constructed.
The reference implant surface was cleaned by a standard cleaning procedure involving the following steps,.
The incidence of capsular contracture is related, among other reasons, to the implant surface.
The chemical activation of the implant surface reduced temporary appliance installation time from 6 to 3 weeks.
During implant placement, damage on the prosthetic connection and implant surface may occur.
Thus, the implant surface is preferably rinsed after the provision of fluorine and / or fluoride thereon.
Furthermore, the above disclosed microroughness is provided by the etching process of the implant surface.
Therefore, HA particles detached from the implant surface have been considered as a serious problem.
Conversely, shorter immersion times generally decrease the amount of material deposited on the implant surface.
SLActive ® - Our unique implant surface for better predictability and shorter healing times.

You'll also be interested in:

Examples of using Implant
The implant was not about being able to hear
I will remove the implant and destroy it
Implant screws have their own color
Show more
Examples of using Surface
An uneven surface increases the risk of overturning
Where ϑ is the measured test surface temperature
All feasible surface and subsurface ECVs
Show more

Search by letter in the English dictionary