Examples of 'von frey' in a sentence
Meaning of "von frey"
Von Frey refers to a type of filament caliper used to measure tactile sensitivity in neurological examinations, commonly in the field of medicine and research
How to use "von frey" in a sentence
Basic
Advanced
von frey
Von frey filament.
The nociceptive threshold was measured by von frey filaments test and hot plate test.
Von Frey filaments were used to evaluate carrageenininduced mechanical hyperalgesia.
Mechanical allodynia was tested by von Frey hairs.
Mice were sacrificed after von Frey measurements were accomplished.
The von Frey monofilament test for mechanical allodynia.
Mechanical threshold was tested using von Frey filament fibers.
Von Frey numbers are logarithmically related to grams of force applied.
Tactile allodynia was measured using von Frey hair aesthesiometers.
The von Frey filament was applied using the up and down method.
Pain was measured as mechanical hypersensitivity using repetitive von Frey filaments.
Threshold data from von Frey filament testing were reported as withdrawal threshold in grams.
Tactile allodynia was assessed by measuring withdrawal thresholds to calibrated von Frey hairs.
Von Frey test results are expressed as grams of pressure required for paw withdrawal.
It can be quantified with the Von Frey test or the paw pressure test.
See also
Sensitivity of the hind paw to mechanical stimulation was tested with von Frey filaments.
A von Frey filament is applied perpendicular to the skin and depressed slowly until it bends.
Pressure threshold values were determined using von Frey filaments test applied to hindpaws.
Insight Von Frey digital filament was used to evaluate nociception.
The mice are then submitted to the mechanical stimulation test with von Frey bristles.
Allodynia was measured by the Von Frey hairs method as described earlier.
The paw withdrawal threshold was determined in response to probing with calibrated von Frey filaments.
Sensitivity response by Von Frey monofilaments allows the evaluation of pressure on skin.
Mechanical and thermal thresholds were determined using von Frey filaments and radiant heat.
Each von Frey hair was applied to the paw for 6 seconds, or until a response occurred.
Nociception was evaluated with a digital Von Frey filament.
Pain Test - The Von Frey test for mechanical allodynia / hyperalgesia induced by CFA.
Mechanical allodynia was measured using the Von Frey test.
Mechanical allodynia was measured with von Frey filaments 15 minutes after CBMS gait analysis.
The PWT was measured using a series of graduated von Frey hairs.
Interestingly, the pre-drug response to von Frey hair stimulation was normalized on day 4 Fig.
Mechanical hyperalgesia / allodynia was measured with the von Frey method.
A test with digital alnalgesimeter, Von Frey filament-type, Insight brand, was used to evaluate nociception.
In this test, tactile allodynia is assessed with calibrated von Frey filaments.
Starting with 0.5 mN, the von Frey monofilament may be applied for approximately 1 sec.
Hyperalgesia may be evaluated with Von Frey monofilaments.
A von Frey hair is a type of aesthesiometer designed in 1896 by Maximilian von Frey.
Nociceptive tests were performed ( electronic von frey and tail immersion test ) weekly.
Pain evaluation was performed by the following instruments, functional incapacity test and Von Frey filament.
The up / down test sequence continues for four additional von Frey applications after the initial detection.
Evaluation of static allodynia Mechanical hypersensitivity was measured using Semmes-Weinstein von Frey hairs.
A trial consisted of several applications of different von Frey filaments ( at a frequency of about 1 Hz ).
For evaluating the analgesic effect of a test substance, employed was a von Frey hair test.
SMH was measured using calibrated von Frey filaments ( Stoelting, Woodale, Ill. ).
Pain threshold for mechanical stimulus was examined by the von Frey hair ( VFH ) test.
Figure 22 is the mean Von Frey examination.
TheY-axis shows mechanical detection thresholds using von Frey filaments.
Mechanical sensitivity was assessed with dynamic von Frey filaments ( IITC, Woodland Hills, CA ).
In three animals the paw was insensitive to even the highest value von Frey filament ( 57 g ).
Evaluation of neuropathic pain ( hereinafter referred to as von Frey test ) was performed as follows.
You'll also be interested in:
Examples of using Frey
Show more
Frey began writing at the age of eleven
Gentle on my mind by glenn frey playing
Frey may not have been the killer
Examples of using Von
Show more
I am sure herr von eckersdorf was very pleased
Von does not talk gang business with me
Laboratory tests for von willebrand disease